video corpo
Add to favorites

#Product Trends

Improve hygiene in Intravitrealen surgery in eye surgeries

Focused Laminar air flow device ensure hygiene in Intravitrealen surgery.

Focused Laminar air flow devices with integrated instrument tables and HEPA filters (H 14) ensure the greatest possible sterility of the instruments and the surgical field during the operation in the operating room and the intervention room. These devices reduce the risk of infection in the operating room and are also inexpensive. Every outpatient surgery room and intervention room can be retrofitted very quickly and easily without expensive renovation work.

Intravitreale injections can be transferred from the Central surgical department. The infeed and unlocking of the patients in the Central-op is very time-consuming and costly. This saves resources and increases efficiency. This technology can be used in any existing operating room and intervention room without annoying and cost-intensive remodeling work. This Laminar air flow is perceived by the staff to be very pleasant as it does not produce cold

Especially in eye surgery, the mobile Laminar air flow devices are ideal. Due to the horizontal flow, both the surgical field and the instruments can be effectively protected by particles and micro-organisms. In conventional supply air blankets, the sterile airflow is mostly hindered by the OP luminaires or surgical microscope. Due to the shortness of the interventions, there is a very high patient flow in the surgery, especially in eye surgery. These patients can bring their own germs into the OP, which can then also become a risk for subsequent patients. Due to the short breaks between the individual operations it is hardly possible to re-sterilize the entire operating room.

In contrast to a conventional operating room, the instruments can always be unpacked and prepared under the protection of the HEPA filter. This has the advantage that the instruments remain sterile. In conventional surgical rooms, the instruments are almost always unpacked in the peripheral area of the operating room and have lost their sterility even before the start of surgery. The instrument table is then simply moved to the operating area and the protective area (sterile zone is then extended by the surgical area.

Operio has an electrical height adjustment which allows the protection area to be individually adapted to the requirements of the surgical situation. The constant cleaning of the air with HEPA filters also reduces the Keimpegel in the entire op.

Improve hygiene in Intravitrealen surgery in eye surgeries

Details

  • Heilbronn, Germany
  • Andreas Kunze