video corpo
Add to favorites

#Product Trends

SteriStay Mother Table – maximum sterility for surgical instruments.

Mother table with integrated laminar flow.

SteriStay Mother Table

The SteriStay Mother Table is the first mother table equipped with an integrated laminar airflow system with HEPA 14 filtration, designed to maintain the sterilization of surgical instruments and effectively prevent surgical infections. Thanks to its advanced technology, this mother table ensures that all instruments and implants remain sterile both during preparation and throughout the entire surgical procedure, significantly improving sterilization conditions in operating rooms.

Many operating rooms are equipped with undersized supply air ceilings that fail to cover the entire surgical field and instrument preparation areas. This is particularly problematic in orthopedics and traumatology, where maintaining the highest hygiene standards is essential to prevent joint infections following hip and knee prostheses.

Challenge: High Microbial Load During Lengthy Surgeries

In specialties such as traumatology, cardiac, neuro, thoracic, and transplant surgery, procedures often extend over several hours. During these prolonged operations, instruments, screws, and implants remain exposed on the instrument table, subjecting them to continuous microbial contamination.

The SteriStay instrument table addresses this issue by providing a continuous sterile environment for instruments and implants throughout the entire surgical procedure. This mobile, height-adjustable table generates a clean airflow over its surface, significantly reducing the presence of particulate matter and microorganisms. Equipped with a built-in HEPA H14 filter, SteriStay eliminates 99.995% of bacteria, microorganisms, and viruses, ensuring that instruments remain sterile during both preparation and surgery.

NORMEDITEC.COM

By integrating the SteriStay instrument table into operating rooms, healthcare facilities can enhance infection control measures, reduce operation times, and expand the protected area in surgeries where existing supply air ceilings are insufficient—all in a flexible, cost-effective, and immediately deployable manner.

Why choose the SteriStay Mother Table?

This device creates a contamination-free environment for the entire duration of the surgical procedure, ensuring the highest level of patient safety.

Advantages of the SteriStay Mother Table

✅ Electric height adjustment

✅ Sterile air filtration

✅ Maximum safety

✅ Extendable length

✅ Comprehensive solution

✅ Improved operating room sterilization

✅ Traceability for defensive medicine – The mother table is equipped with sterile covers featuring dual traceability for defensive medicine: an adhesive label to be placed in the patient’s file and a barcode that is scanned by the laminar airflow system and stored in memory.

SteriStay Mother Table – maximum sterility for surgical instruments.

Details

  • 74239 Hardthausen am Kocher, Germany
  • Normeditec