Arteriosclerosis detector ADS-6000B operation guide
ADS-6000B arteriosclerosis detector is an efficient, accurate and convenient medical device, which provides strong support for arteriosclerosis detection.
In today's society, cardiovascular and cerebrovascular diseases have become one of the main culprits threatening human health, and arteriosclerosis as its core cause, we need to be highly vigilant. In order to more effectively conduct early detection and prevention of arteriosclerosis, the ADS-6000B arteriosclerosis detector of Pinyuan Medical can evaluate vascular health status by measuring blood pressure, pulse wave conduction velocity (PWV) and ankle-brachial index (ABI), which provides an important basis for clinical diagnosis and treatment.
Preparation before operation
1. Check the equipment: Ensure that the ADS-6000B arteriosclerosis detector is in good appearance and has no damaged or loose parts. Check whether accessories such as power cables, sensors, and cuffs are complete and functional.
2. Environmental requirements: The operating environment should be quiet and dry to avoid electromagnetic interference. The room temperature is controlled within the appropriate range to ensure patient comfort.
3. Patient preparation: Patients should wear loose clothing to facilitate measurement of site exposure. Before the measurement, keep quiet to avoid violent exercise or emotional fluctuations affecting the measurement results.
Operation procedure
1. Power on and initialize: Power on, press the power button, and wait for the device to start and complete initialization.
2. Patient information input: Through the touch screen or external computer workstation, input the basic information of the patient, such as name, age, gender, etc.
3. Preparation of measurement site: Tie the cuff to the designated part of the patient's upper arm and lower limb to ensure that the cuff is smooth and wrinkle-free. Place the sensor and ECG clip correctly in the specified position.
4. Start measuring: Select the "Start Measuring" option on the touch screen, and the device will automatically measure blood pressure and calculate pulse wave conduction velocity (PWV) and ankle-brachial index (ABI).
5. View and save the result: After the measurement is completed, the device will display the measurement result. Detailed reports can be viewed on the touch screen.
Matters needing attention
1. Measurement accuracy: Ensure that the cuff size matches the circumference of the patient's limb to improve measurement accuracy. Avoid applying grease or skin care products on the measurement site to avoid affecting the normal work of the sensor.
2. Patient comfort: In the measurement process, pay attention to the patient's feelings, timely adjust the cuff tightness to ensure the comfort of patients.
3. Equipment maintenance: Clean and maintain the equipment regularly to keep the appearance of the equipment clean and extend the service life.
4. Data security: Properly keep patient data to ensure data security and privacy.
troubleshooting
If the equipment is faulty or abnormal during use, contact the equipment supplier or professional technical personnel for maintenance. Do not disassemble or repair the equipment yourself to avoid damage or safety hazards.
ADS-6000B arteriosclerosis detector is an efficient, accurate and convenient medical device, which provides strong support for arteriosclerosis detection. Standardized operation and maintenance can ensure the long-term stable operation of the equipment and escort the health of patients.