#Product Trends
Isolation stretcher
Isolation chamber for transport of infectious or immunocompromised patient
CTMP is a transport chamber which protects the patient or the external environment from any cross contamination that could occur during land or air transport.
The chamber can operate in negative or positive pressure mode:
Negative pressure: to transport infected patients or patients suspected of biological contaminations such as : COVID-19, viral hemorrhagic fever, SRAS (severe acute respiratory syndrome), smallpox, tuberculosis, meningitis, Ebola, etc.
Positive pressure : for protection and transport of immuno-compromised patients : bubble child, aplasia, etc.
Advantages:
CTMP provides a stress-free transportation:
- For medical staff in charge of transport who is protected against any risk of contamination
- For the ambulance driver who does not need to wear any special protective outfit and to disinfect the vehicle
- For hospital reception staff who can safely take care of the patient without any risk of contamination of the premises or other patients and who can easily clean the chamber.
Our references are:
- Service de Santé de l’Armée Française (Health Services of the French Army).
- E.P.R.U.S. (Etablissement de Préparation et de Réponse aux Urgences Sanitaires) – France
- B.S.P.P. (Brigade des Sapeurs- Pompiers de Paris – Paris Firefighters Association)
- S.A.M.U. de La Réunion – France (National Health Services)
- S.A.M.U. de Nouméa – Nouvelle-Calédonie (National Health Services)
- Main Moscow Hospital -Russian Federation
- Marrakech University Hospital – Morocco
- National Health Services in Algeria - S.A.M.U.
- Flying Doctors – Kenya
- Ambulance Service Dubai - UAE
Technical characteristics :
• Control screen with audible and visual operation alarms
• Medicalization of the patient: 6 medical entries of diameter 4mm to 22mm allow to use all types of medical equipment
• Possible re-intubation of the patient
• Overpressure (+50 Pa) or depression (-50Pa) of the patient by simple and secure switching
• H14 filtration (incoming and outgoing) is 99.995% MPPS according to standard EN 1822
• Visual communication and permanent voice with the patient to fight against the feeling of claustrophobia
- Immobilization of the patient by 3-point harness
- Anchorage to the floor of an ambulance or aircraft by approved system (Option)
Operating autonomy :
• On battery: 6 hours
• Unlimited on external power supply 12VDC or 110-240VAC / 50-60Hz
• Recharging the battery with 110-240VAC / 50-60Hz power supply